Laboratories accredited by CNAS

broken image

Xiamen Taihang Technology Co., Ltd. owns CNAS (China National Accreditation Service for Conformity Assessment) and ILAC (International Laboratory Accreditation Cooperation) accredited laboratories, covering an area of over 1000 square meters. We specialize in providing differentiated and personalized experimental verification services across various industries, ensuring technical support for online product performance and quality supervision. Our company also offers professional services for product development platforms and technical research platforms.

Lightning Surge Laboratory

broken image

Main Application:

1. Testing Surge Protection Devices (SPDs)

2. Simulating Lightning Strikes

3. Evaluating Insulation and Dielectric Strength

4. Testing Lightning Early Warning Systems

5. Assessing the Impact of Lightning on Communication Lines and Power Grids

6. Developing Lightning Protection Standards

Technical Specifications:

Maximum Surge Current

8/20μs: 260kA

10/350μs: 60kA

10/1000μs: 10kA

Role in product quality assurance:

1. Verifying the Effectiveness of Surge Protection Devices (SPDs)

2. Improving Product Resistance to Lightning Impacts

3. Ensuring Long-Term Stability and Durability

4. Assessing Overall System Performance and Reliability

5. Enhancing Quality Control Standards and Certifications

6. Identifying Potential Design Flaws for Improvement

7. Product Lifetime Prediction

Testing Scope:

Voltage protection level and action load test of surge protectors.

Standards Compliance:

  • IEC 61643.11
  • GB 18802.1-2011, GB/T 18802.21-2004, YD/T 1235.2-2002, etc.

SPD Safety Laboratory

broken image

Technical Specifications:

Thermal Stability Test Current: 0-640mA.

Transient Overvoltage Test Output Voltage: 242VAC, 484VAC, 600VAC, 800VAC, 1000VAC, 1200VAC, 1420VAC selectable.

Transient Overvoltage Test Output Current: Adjustable from 10A to 300A.

Transient Overvoltage Test Duration: Selectable from 1 to 10 cycles, or continuous power-on mode.

Testing Scope:

Thermal stability, ignition boundary conditions, and transient overvoltage fault tests for surge protectors.

Standards Compliance:

  • IEC 61643.11

  • GB 18802.1-2011, GB/T 18802.21-2004, YD/T 1235.2-2002, e

Electromagnetic Compatibility (EMC) Laboratory

broken image

Tests include conducted emissions at low frequency, electrostatic discharge, electrical fast transients, conducted susceptibility, voltage dips, spectrum analysis, and network analysis.

Standards Compliance:

  • IEC 61643.11
  • GB 18802.1-2011, GB/T 18802.21-2004, YD/T 1235.2-2002, etc.

Environmental Laboratory

broken image

Technical Parameters:

Temperature Range: -40°C to +150°C

Testing Scope:

Salt spray, vibration, high temperature, low temperature, humidity, cyclic damp heat, etc.

Standards Referenced:

  • IEC 61643.11
  • GB 18802.1-2011, GB/T 18802.21-2004, YD/T 1235.2-2002, GBT 2423.1-2008, GBT 2423.2-2008, etc.

Chemical and Physical Laboratory

broken image

Testing Scope:

Metallographic analysis

Spectral analysis

RoHS compliance testing

Flame retardancy testing

Comparative tracking index (CTI)

Dielectric withstand testing, etc.

Standards Compliance:

  • IEC 61643.11
  • GB 18802.1-2011, GB/T 18802.21-2004, YD/T 1235.2-2002, etc.

Mechanical Laboratory

broken image

Testing Scope:

Pendulum impact testing

Tensile testing

Compression testing

Torque testing

Hardness testing, etc.